2 August 2025
An auxiliary pressure channel allows to the health practitioner to obtain valuable practical information. The doctor can measure the pressure directly in the trachea and esophagus. The pressure in esophagus is equal to the intrapleural pressure.
auxiliary pressure.pngAmong the main principles of protective artificial lung ventilation the PEEP is considered to be an important component for the prevention of atelectotrauma.

P transpulmonary = P alveolar — P pleural

Transpulmonary pressure is the only objective criterion for setting up PEEP. Its monitoring allows reducing or eliminating lung injuries during the ventilation.