Intensive Care Ventilator Zisline MV350 Version K0
Intended use: ICUs, ORs, intra hospital transportation
Patient types: adult, pediatric, neonatal (from 500 g)
Display: 15” color touchscreen
Air supply: built-in turbine
Oxygen supply: hospital pipeline, cylinder or O₂ concentrator (option)
Power supply: 100–250 V, 50/60 Hz, built-in battery for 4 to 6 hours
Basic universal ventilation
Details
Patient types: adult, pediatric, neonatal (from 500 g)
Display: 15” color touchscreen
Air supply: built-in turbine
Oxygen supply: hospital pipeline, cylinder or O₂ concentrator (option)
Power supply: 100–250 V, 50/60 Hz, built-in battery for 4 to 6 hours
Basic universal ventilation
Intensive Care Ventilator Zisline MV350 Version K0
Ventilation parameters
|
Tidal volume |
1–3000 ml |
|
Respiratory rate |
1–150 bpm |
|
Inspiratory time |
0.2–15 s |
|
Flow trigger sensitivity |
0.1–20 lpm |
|
Pressure trigger sensitivity |
0.5–20 cm H₂O |
|
PEEP |
0–50 cm H₂O |
|
Inspiratory pressure |
0–100 cm H₂O |
|
Pressure support |
0-80 cm H₂O |
Default ventilation modes
|
Mandatory ventilation |
Controlled mandatory lung ventilation with volume control | CMV VCV |
| Controlled mandatory ventilation with pressure control | CMV PCV | |
| Ventilation with inspiration pressure control and guaranteed delivery of target tidal volume | PCV VG | |
|
Synchronized intermittent mandatory ventilation |
Synchronized Intermittent Mandatory Ventilation mode with volume control with pressure support | SIMV VC |
| Synchronized Intermittent Mandatory Ventilation mode with pressure control with pressure support | SIMV PC | |
| Synchronized Intermittent Mandatory Ventilation mode with pressure control and delivery of target tidal volume with pressure support | SIMV DC | |
|
Spontaneous breathing |
Continuous Positive Airway Pressure. The ventilation mode supporting spontaneous breathing with the continuous positive airway pressure | CPAP+PS |
| The spontaneous ventilation mode with the continuous positive airway pressure with the pressure support set by the device and delivery of a target respiratory volume | CPAP+VS | |
| Airway pressure release ventilation mode | APRV | |
| Spontaneous ventilation mode at two levels of continuous positive airway pressure with pressure support of spontaneous breaths | BiSTEP + PS | |
|
Non-invasive ventilation |
Non-invasive ventilation | NIV |
| High flow oxygen therapy mode |
HF_O₂ |
|
| Non-invasive respiratory mode with continuous pressure support using a nasal cannula or mask |
nCPAP |
|
| Nasal intermittent mandatory ventilation with pressure control and pressure support of spontaneous inspirations using nasal cannulas or masks | nIMV | |
|
Back-up mode |
Automatic backup ventilation mode in case of apnea |
Apnea |
Start-up delivery set / Quantity, pcs.
| Electronic unit | 1 |
| Power cable | 1 |
| High pressure oxygen hose | 1 |
| Arm for breathing circuit | 1 |
| Mobile trolley | 1 |
| Filter regulator | 1 |
General consumables and disposables
| Proximal flow sensor | 1 |
|
Cable for proximal flow sensor |
1 |
| Breathing bag, 0.5 L | 1 |
| Filter bacterial, pediatric, disposable | 1 |
| Patient circuit disposable RT224 | 1 |
| Patient circuit disposable RT225 | 1 |
| Generator Miniflow | 1 |
| Generator Medijet | 1 |
| Medin set | 1 |
Spare parts
| Fuse 2 A | 2 |
| Ring | 2 |
| Filter element (microfilter) | 1 |
| Dust filter | 2 |
| Membrane (flow sensor) | 1 |
Documents
|
User Manual |
1 |
Integrated features
- Alveolar recruitment maneuver
- Oxygenation
- Suction
- Leak compensation
- Manual breath
- Auxiliary pressure measurement port
Additional options
- iSV mode
- CO₂ option, including sensor and reusable airway adapter (for adult / pediatric / neonatal)
- SpO₂ option, including adult and pediatric reusable sensors
- Ultrasound O₂ Sensor (maintenance free)
- Depth of Anesthesia and Sedation Monitoring
- Low pressure O₂ port
- Gateway Hub (HL7 format)
Articles