Zisline T100 Ventilator

Zisline T100 Ventilator
Download the brochure
Transport ventilator for all patients, including preterm babies 
Peculiarities
Central O₂ pipeline, cylinders, oxygen concentrator
Universal bracket VESA
MIS / PDMS data transfer
Technologies
10” touch screen LCD display
8 hours of battery life / hot swap battery
Proximal flow sensor for neonates
Mainstream CO₂ sensor
SpO₂ sensor
Versatility
Zisline T100 Ventilator
is designed for controlled and assisted
artificial ventilation of adults, children
and neonates, including extremely low
birth weight neonates from 500 g
Mainstream CO 2 Sensor
Proprietary original capnometry technology
No calibration required by reference gases
Response time less 30 ms
Reusable autoclavable adapters
For all patient types
Proximal Flow Sensor
For neonates only
Digital and precise
Small tidal volume
Reusable autoclavable or disposable
No sensor calibration required
Distal Flow Sensor
Autoclavable
Integrated into exhalation valve
Easy to maintain and clean

Products

Preview picture
Zisline T100 Ventilator

10`` touch screen display
All patients, including preterm babies
15 ventilation modes maximum
catalog

Comparison of configurations
Download the table
Intended use: transport, emergency
Patient types: adult, pediatric, neonatal (from 500 g)
Display: 10.1” color touchscreen
Air supply: built-in turbine
Oxygen supply: hospital pipeline, cylinder or O₂ concentrator
Power supply: 100–240 V, 50/60 Hz, built-in battery 86 hours

* with Neonatal option
Description / Model
Zisline T100
Tidal volume    20–3000 / 2–3000* ml
Screen size, inches    10.1

Ventilation modes

Mandatory ventilation
 
CMV VCV
CMV PCV  
+
PCV VG
+ 
Synchronized intermittent
mandatory ventilation
 
SIMV VC
SIMV PC
+
SIMV DC      + 
Spontaneous breathing
     
CPAP+PS
+   
CPAP+VS      +
APRV
+
BiSTEP      + 
Non-invasive ventilation
   
NIV
+
HF_O₂
+
nCPAP      Option 
nIMV      Option 
Back-up mode
Apnea
+
Adaptive ventilation
iSV
+

Integrated features

Description / Model Zisline T100
Mainstream CO₂
Option
Volumetric capnometry
Option
Calculation of cardiac output
Option
Auxiliary pressure measurement port
+
SpO₂
Option
Low pressure port
+
Show in full
Сравнение комплектаций
Скачать таблицу
Intended use: transport, emergency
Patient types: adult, pediatric, neonatal (from 500 g)
Display: 10.1” color touchscreen
Air supply: built-in turbine
Oxygen supply: hospital pipeline, cylinder or O₂ concentrator
Power supply: 100–240 V, 50/60 Hz, built-in battery 86 hours

* with Neonatal option
Description / Model
Zisline T100
Tidal volume    20–3000 / 2–3000* ml
Screen size, inches    10.1

Ventilation modes

Mandatory ventilation
 
CMV VCV
CMV PCV  
+
PCV VG
+ 
Synchronized intermittent
mandatory ventilation
 
SIMV VC
SIMV PC
+
SIMV DC      + 
Spontaneous breathing
     
CPAP+PS
+   
CPAP+VS      +
APRV
+
BiSTEP      + 
Non-invasive ventilation
   
NIV
+
HF_O₂
+
nCPAP      Option 
nIMV      Option 
Back-up mode
Apnea
+
Adaptive ventilation
iSV
+

Integrated features

Description / Model Zisline T100
Mainstream CO₂
Option
Volumetric capnometry
Option
Calculation of cardiac output
Option
Auxiliary pressure measurement port
+
SpO₂
Option
Low pressure port
+
Articles

Capnometry and volumetric capnometry (VCO2 + ETCO2)
This monitoring method is recommended for use in intensive care units and operating rooms to improve patient safety. Capnography allows to assess the endotracheal tube location, the resuscitation effectiveness. This type of monitoring is necessary for patients with increased intracranial pressure.
Capnometry and volumetric capnometry (VCO2 + ETCO2)
1 December 2025
Auxiliary pressure Paux
An auxiliary pressure channel allows to the health practitioner to obtain valuable practical information. The doctor can measure the pressure directly in the trachea and esophagus. The pressure in esophagus is equal to the intrapleural pressure.
Auxiliary pressure Paux
2 August 2025
Intelligent Support Ventilation — iSV mode
The intelligent support ventilation (iSV) mode provides the target volume of minute ventilation at any level of patient‘s spontaneous respiratory activity. iSV automatically adjusts the support pressure level in each respiratory cycle, depending on the changes in the parameters of the bronchopulmonary system. The parameters of iSV are determined extremely simply — by the patient‘s height and gender.
Intelligent Support Ventilation — iSV mode
28 July 2025
Extended Respiratory Monitoring
Extended respiratory monitoring allows to set comfortable and safe ventilation parameters in accordance with the respiratory needs of the patient.
Extended Respiratory Monitoring
13 January 2025
Back to the list

Manufacturing medical devices

Supporting Anesthesiology, Intensive care and Emergency medical care

Contacts

+7 (343) 304-60-57
info@treat-on.com
Bajova str. 33, 620133 Ekaterinburg, Russian Federation

© 2026  Triton Electronic Systems Ltd
website development
Privacy policy
Rules for the use of website materials