Font size
Background and font color
Images
Text scoring
Regular version of the site
Медицинское оборудование
для анестезиологии и интенсивной терапии
+7 (343) 304-60-57
+7 (343) 304-60-57
Email
info@treat-on.com
The address
Bajova str. 33, 620133 Ekaterinburg, Russian Federation
info@treat-on.com
Contact
Catalog
  • Intensive Care and Respiratory Support
  • Anesthesiology
About
  • About company
  • Company history
  • Our team
    • Board of directors
    • International sales
Media
  • News
  • Blog
  • Technology
  • Documents
Services
  • Service
  • Request for service
  • The complaint
  • Connecting to your merchant profile
Contacts
OEM
+7 (343) 304-60-57
+7 (343) 304-60-57
Email
info@treat-on.com
info@treat-on.com
Contact
Contact
  • Catalog
    • Catalog
    • Intensive Care and Respiratory Support
    • Anesthesiology
  • About
    • About
    • About company
    • Company history
    • Our team
      • Our team
      • Board of directors
      • International sales
  • Media
    • Media
    • News
    • Blog
    • Technology
    • Documents
  • Services
    • Services
    • Service
    • Request for service
    • The complaint
    • Connecting to your merchant profile
  • Contacts
  • OEM
Contact
  • Cabinet
  • Bajova str. 33, 620133 Ekaterinburg, Russian Federation
  • info@treat-on.com
Catalog
—
Intensive Care and Respiratory Support from Treaton
—Intensive Care ventilator Zisline MV300

Intensive Care ventilator Zisline MV300

Intensive Care ventilator Zisline MV300
Download the brochure
Multifunctional ventilator for Intensive care with advanced respiratory monitoring
Built-in turbine
Independed from compressed air sources. The turbine does not require special maintenance and ensures the operation for 40 000 hours
Advanced patient monitoring
Mainstream CO₂
Volumetric CO₂
Evaluation of patients metabolic needs
Auxiliary pressure
SpO₂
Respiratory mechanics
Cardiac output by Fick method
13 ventilation modes
Mandatory ventilation modes
Modes of spontaneous breathing
Non-invasive ventilation modes
Intelligent ventilation
High-flow oxygen therapy mode
Reliable autoclavable exhalation valve
Ventilator is equipped with exhalation valve, which can be easily disconnected from the device and processed in autoclave

Products

Preview picture
Zisline MV300 Version K0

Basic ventilation
catalog
Preview picture
Zisline MV300 Version K1

Mainstream CO₂
Metabolic evaluation (indirect calorimetry)
Volumetric capnometry
Calculation of cardiac output
catalog
Preview picture
Zisline MV300 Version K2

Mainstream CO₂
Metabolic evaluation (indirect calorimetry)
Volumetric capnometry
Calculation of cardiac output
Auxiliary pressure measurement port
Adaptive ventilation iSV mode
catalog

Comparison of configurations
Download the table
Intended use: ICUs, ORs, intra hospital transportation
Patient types: adult, pediatric, infant
Display: 15” color touchscreen
Air supply: built-in turbine
Oxygen supply: hospital pipeline, cylinder or O2 concentrator (option)
Power supply: 100–250 V, 50/60 Hz, built-in battery for 4 to 6 hours

Description / Model / Version Zisline MV300 K0
Zisline MV300 K1 Zisline MV300 K2
Tidal volume, ml
10-3000 10-3000 10-3000
Screen size, inches 15   15 15 15

Ventilation modes

Mandatory ventilation
 
CMV VCV
CMV PCV  
+ + +
PCV VG
+  +  + 
Synchronized intermittent
mandatory ventilation
 
SIMV VC
SIMV PC
+ + +
SIMV DC      +  +  + 
Spontaneous breathing
     
CPAP+PS
+    + +
CPAP+VS      + +  + 
APRV
+ +  + 
BiSTEP      +  +  + 
Non-invasive ventilation
 
NIV
+ + +
HF_O₂
+ +  +
Back-up mode
Apnea
+ + +
Adaptive ventilation
iSV
Option
Option
+

Integrated features

Description / Model / Version Zisline MV300 K0
Zisline MV300 K1
Zisline MV300 K2
Mainstream CO₂
Option + +
Volumetric capnometry
Not available
+ +
Calculation of cardiac output
Not available + +
Metabolic evaluation (indirect calorimetry)
Not available + +
Auxiliary pressure measurement port
Not available Not available +
SpO₂
Option Option    Option   
Low pressure port
Option Option Option
Ultrasound O₂ sensor
Option Option Option   
Depth of anesthesia and sedation
monitoring
Option
Option Option
HL7 data export format
Option Option  Option 
Show in full
Сравнение комплектаций
Скачать таблицу
Intended use: ICUs, ORs, intra hospital transportation
Patient types: adult, pediatric, infant
Display: 15” color touchscreen
Air supply: built-in turbine
Oxygen supply: hospital pipeline, cylinder or O2 concentrator (option)
Power supply: 100–250 V, 50/60 Hz, built-in battery for 4 to 6 hours

Description / Model / Version Zisline MV300 K0
Zisline MV300 K1 Zisline MV300 K2
Tidal volume, ml
10-3000 10-3000 10-3000
Screen size, inches 15   15 15 15

Ventilation modes

Mandatory ventilation
 
CMV VCV
CMV PCV  
+ + +
PCV VG
+  +  + 
Synchronized intermittent
mandatory ventilation
 
SIMV VC
SIMV PC
+ + +
SIMV DC      +  +  + 
Spontaneous breathing
     
CPAP+PS
+    + +
CPAP+VS      + +  + 
APRV
+ +  + 
BiSTEP      +  +  + 
Non-invasive ventilation
 
NIV
+ + +
HF_O₂
+ +  +
Back-up mode
Apnea
+ + +
Adaptive ventilation
iSV
Option
Option
+

Integrated features

Description / Model / Version Zisline MV300 K0
Zisline MV300 K1
Zisline MV300 K2
Mainstream CO₂
Option + +
Volumetric capnometry
Not available
+ +
Calculation of cardiac output
Not available + +
Metabolic evaluation (indirect calorimetry)
Not available + +
Auxiliary pressure measurement port
Not available Not available +
SpO₂
Option Option    Option   
Low pressure port
Option Option Option
Ultrasound O₂ sensor
Option Option Option   
Depth of anesthesia and sedation
monitoring
Option
Option Option
HL7 data export format
Option Option  Option 
Articles

Capnometry and volumetric capnometry (VCO2 + ETCO2)
This monitoring method is recommended for use in intensive care units and operating rooms to improve patient safety. Capnography allows to assess the endotracheal tube location, the resuscitation effectiveness. This type of monitoring is necessary for patients with increased intracranial pressure.
Capnometry and volumetric capnometry (VCO2 + ETCO2)
1 December 2025
Evaluation of patient‘s metabolic needs

The peculiarity of patients in intensive care and resuscita tion units is metabolic insta bility caused by the severity of the condition, artificial lung ventilation, sedation,  analgesia and extracorporeal detoxification methods. Therefore, metabolic monitoring for such patients is of great importance.

Evaluation of patient‘s metabolic needs
10 September 2025
Auxiliary pressure Paux
An auxiliary pressure channel allows to the health practitioner to obtain valuable practical information. The doctor can measure the pressure directly in the trachea and esophagus. The pressure in esophagus is equal to the intrapleural pressure.
Auxiliary pressure Paux
2 August 2025
Intelligent Support Ventilation — iSV mode
The intelligent support ventilation (iSV) mode provides the target volume of minute ventilation at any level of patient‘s spontaneous respiratory activity. iSV automatically adjusts the support pressure level in each respiratory cycle, depending on the changes in the parameters of the bronchopulmonary system. The parameters of iSV are determined extremely simply — by the patient‘s height and gender.
Intelligent Support Ventilation — iSV mode
28 July 2025
Depth of Anesthesia and Sedation Monitoring
MGA Depth of Anesthesia and Sedation Module is designed to provide long and continuous monitoring of the Brain Activity Index (AI). 
Application: anesthesiology, including perioperative period, resuscitation, intensive care, procedural sedation.
Depth of Anesthesia and Sedation Monitoring
25 March 2025
Extended Respiratory Monitoring
Extended respiratory monitoring allows to set comfortable and safe ventilation parameters in accordance with the respiratory needs of the patient.
Extended Respiratory Monitoring
13 January 2025
Back to the list

Manufacturing medical devices

Supporting Anesthesiology, Intensive care and Emergency medical care

Catalog
Intensive Care and Respiratory Support
Anesthesiology
OEM
About
About
Company history
Our team
Reviews
Media
News
Blog
Technology
Documents
Contacts

+7 (343) 304-60-57
info@treat-on.com
Bajova str. 33, 620133 Ekaterinburg, Russian Federation

© 2026  Triton Electronic Systems Ltd
website development
Privacy policy
Rules for the use of website materials